查看全文 作  者:Jiaming [1]LI;Jinyu [1]WEN;Xingning [1]HAN 高影响力作者 机构地区:[1]State Key Laboratory of Advanced Electromagnetic Engineering and Technology,School of Electrical and Electronic Engineering,Huazhong University of Science and Technology,Wuhan 430074,China高影响力机构 出  处:《Journal of Modern Power Systems and Clean Energy》索引2015年第3卷第1期,共9页高影响力期刊 基  金:This work was supported by the National Basic Research Program of China(No.2012CB215106);State Grid Corporation of China(No.52150014006W). 摘  要:The paper proposes a stochastic unit commitment(UC)model to realize the low-carbon operation requirement and cope with wind power prediction errors for power systems with intensive wind power and carbon capture power plant(CCPP).A linear re-dispatch strategy is introduced to compensate the wind power deviation from the spot forecast.The robust optimization technique is employed to obtain a reliable commitment plan against all realizations of wind power within the uncertainty set given by probabilistic forecast.The proposed model is validated with IEEE 39-bus system.The advantages of flexible CCPPs are compared to the normal coal-fueled plants and the impacts of robustness controlling are discussed. 关 键 词:Low-carbon unit commitment Carbon capture and storage Linear re-dispatch strategy Robust optimization