维普中文期刊产品整合服务
2篇 您的检索式:作者名="AYong Yu"
    题名 作者 年代 出处 被引量
1Ultrasound Biomicroscopy of Iris-claw Phakic Intraocular Lens Implantation显示文摘Purpose: To study in situ the intraocular position of iris-claw phakic intraocular lens (ICPIOL) in myopic eyes using ultrasound biomicroscopy (UBM). Methods: UBM echograms of the anterior segment were taken preoperatively and 62 to 115 days postoperatively in 6 eyes implanted with the Verisys ICPIOL (AMO). The echograms were assessed for the effect of the ICPIOL on iris tissue. Results: The preoperative distance between the corneal endothelium and the lens ranged from 2.96 to 3.09 mm, and the postoperative distance between the ICPIOL and the corneal endothelium, from 1.86 to 2.03 mm. The distance between the lens and the posterior surface of the ICPIOL ranged from 0.61 to 0.76 mm. The distance between the superior, inferior optic edge and the iris ranged from 0.49 to 1.00 mm, 0.21 to 0.51 mm respectively. The shortest distance between the ICPIOL haptics and the angle of anterior chamber ranged from 1.25 to 1.65 mm. The indentation of iris tissue by the ICPIOL haptics without pigmentary dispersion and distortion of posterior curvature of iris was observed. Conclusion : Adequate space is maintained between the Verisyse myopic ICPIOL and the corneal endothelium, angle, and crystalline lens. Haptic indentation of the iris without pigment erosion and distortion of iris curvature is noted. The ICPIOL implanted in phakic eyes is a safe alternative for treatment of high myopia.Ayong Yu 2006眼科学报2006,22,1:1
2High intercorneal symmetry in corneal biomechanical metrics显示文摘Backgroud:To evaluate the symmetry of corneal biomechanical metrics,measured using an ocular response analyzer(ORA)and self-built corneal inflation test platform,in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure(IOPp).Methods:Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation.IOP was increased from 7.5 to 37.5 mmHg with 7.5 mmHg steps and biomechanical metrics were acquired using the ORA.At least 3 examinations were performed at each pressure stage.Two biomechanical metrics,corneal hysteresis(CH)and corneal resistance factor(CRF)were recorded and analyzed as a function of IOPp.Corneal specimens were then excised from the intact ocular globe and tested under inflation conditions up to 45.7 mmHg posterior pressure.The experimental pressure-deformation data was analyzed using an inverse modeling procedure to derive the stress-strain behavior of the cornea.Results:A comparison of corneal shape parameters showed no statistically significant difference(P>0.05)between bilateral eyes.Similarly,there were no statistically significant differences in values of CH,CRF and corneal stiffness(as measured by the tangent modulus,Et)between bilateral eyes(CH:F=0.94,P=0.54;CRF:F=4.42,P=0.35;Et:F=3.15,P=0.12)at different pressure levels.IOPp was highly correlated with CRF while the relationship with CH was less pronounced.Conclusions:An obvious interocular symmetry in biomechanical metrics is found in this research.IOP has been shown to have important influences on the value of CRF provided by ORA.XiaoBo Zheng FangJun Bao Brendan Geraghty JinHai Huang AYong Yu QinMei Wang 2016Eye and Vision2016,3,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费