维普中文期刊产品整合服务
8篇 您的检索式:作者名="Baoquan Wan"
    题名 作者 年代 出处 被引量
1Improved breakdown strength and energy density of polyimide composites by interface engineering between BN and BaTiO3 fibers显示文摘Conventionally,interface effects between polymers and fillers are essential for determining the breakdown strength and energy storage density of polymer-based dielectric composites.In this study,we found that interface effects between different fillers have similar behavior.BN and Ba TiO3 fiber composite fillers with three different interface bonding strengths were successfully achieved by controlling composite processes(BT-fiber/BNBaoquan Wan Haiyu Li Yunhui Xiao Zhongbin Pan Qiwei Zhang 2021Journal of Materials Science & Technology2021,,15:4
2Statistical Analysis of Radio Interference of 1000 kV UHV AC Double-circuit Transmission Lines in Foul Weather显示文摘Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode.Huichun Xie Xiang Cui Baoquan Wan Jiangong Zhang 2016CSEE Journal of Power and Energy Systems2016,2,2:2
3Corona Onset Voltage Gradient of Bundle Conductors for EHV/UHV AC Power Lines in Corona Cages Considering Altitude Correction显示文摘The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly estimate the COG of single conductors and is not applicable to large cross-section bundle conductors.In this paper,experiments are conducted to investigate the corona characteristics of a whole series of bundle conductors at different altitudes,and a prediction formula is proposed for the COG of large cross-section bundle conductors on AC transmission lines considering the altitude correction.The calculated values using the proposed prediction formula are compared with the experimental values of the COG in two cases:UHV eight-bundle conductors at an altitude of 19 m;500 kV UHV four-bundle conductors in Wuhan,Xining,Geermu,and Nachitai at four different altitudes.The results show that the use of the formula can predict the COG of bundle conductors with the radius of 1.34 cm to 1.995 cm and the number of subconductors of 4 to 12 at altitudes of 19 m to 4000 m above the mean sea level.The research findings can provide a reference for the design of EHV and UHV overhead transmission lines and even those in higher voltage levels.Shilong Huang Yunpeng Liu Shaoshuai Chen Daran Liu Wangling He Baoquan Wan 2020CSEE Journal of Power and Energy Systems2020,6,3:1
4Preparation and Properties of Epoxy Piezoelectric Vibration Reduction Composites显示文摘The epoxy resin (E-51) was used as polymer matrix,conductive carbon black (CB) as conductive filler,and PZT was used to prepare a composite by curing.The effects of PZT and CB content on the properties of PZT/ CB/ EP piezoelectric composite were studied.When the PZT content reaches 40 wt%,the optimized vibration attenuation properties of PZT/CB/EP materials could be achieved with a loss factor of 0.9 from room temperature to 60 ℃.With the increase of PZT content,the bending strength of PZT/CB/EP piezoelectric composite vibration reduction material firstly increased from 45 MPa to 65 MPa and then decreased to 38 MPa.At room temperature,the dielectric constant increased from 7 to 50,and the dielectric loss increased from 0.1 to 0.5.汤重 郝华 WAN Baoquan CAO Minghe YAO Zhonghua LIU Hanxing 2021Journal of Wuhan University of Technology(Materials Science)2021,36,1:0
5Recyclability and Self-Healing of Dynamic Cross-Linked Polyimide with Mechanical/Electrical Damage显示文摘Recyclability and self-healing are two most critical factors in developing sustainable polymers to deal with environmental pollution and resource waste.In this work,a dynamic cross-linked polyimide insulation film with full closed-loop recyclability is successfully prepared,which also possesses good self-healing ability after being mechanical/electrical damaged depending on the Schiff base dynamic covalent bonds.The recycled and self-healed polyimide film still maintain its good tensile strength(r t)>60 MPa with Young’s modulus(E)>4 GPa,high thermal stability with glass transition temperature(T g)>220℃,and outstanding insulation property with breakdown strength(E 0)>358 kV mm^(-1),making it a very promising low energy consumption and high temperature resistant insulation material.The strategy of using Schiff base dynamic covalent bonds for reversible repairing the structure of high T g polyimides promotes the wider application of such sustainable and recyclable material in the field of electrical power and micro-electronics.Baoquan Wan Ming-Sheng Zheng Xing Yang Xiaodi Dong Yuchao Li Yiu-Wing Mai George Chen Jun-Wei Zha 2023Energy & Environmental Materials2023,6,1:0
6Radio Interference Characteristic of Ultra-high Voltage AC Transmission Lines by Using Stochastic Modeling显示文摘For developing ultra-high voltage(UHV) AC power transmission systems,it is important to precisely estimate and to limit the radio interference(RI) level of power lines.Based on the stochastic characteristics in amplitude and repetition rate of induced corona current,by using the probability theory and mathematical statistics,we establish a stochastic model for the wide-sense stationary random process of corona discharges.Then combining the stochastic model with model-propagation-analysis method,the RI levels under three-phase UHV AC transmission lines are calculated.The results of the calculation based on stochastic model method and International Council on Large Electric Systems(CIGRE) excitation function are compared with that based on semi-empirical method and some other excitation functions.The stochastic model based on different excitation functions is also adopted to simulate the RI levels under finite test lines with two opened terminations.The results indicate that with the same average maximum gradient on conductor surface and the same conductor type,the number of corona discharge per unit length is one of the main reasons that causes the difference between different excitation functions.It is also concluded that for a long test line,the effect of standing wave on RI field strength is negligible in the middle of the line,but obvious near both terminations: for a 10-km line,the maximum difference in RI field strength is 2.78 dB,between the peak value of the standing wave near the ends and the steady value near the middle of the line.HE Wangling WAN Baoquan PEI Chunming ZHANG Jiangong HE Junjia GUO Haozhou 2013高电压技术2013,39,10:0
7Audible Noise Performance of High Voltage AC Conductor Bundles at an Altitude of 226lm显示文摘Extra or ultra-high voltage transmission lines can exhibit strong corona discharge and generate severe audible noise(AN)at high altitudes,which has become a critical limiting factor for power lines construction.However,the AN data of bundle conductors at high altitudes are very rare,which cannot adequately support the power utilities to make reasonable conductor selections.In this paper,a sound pressure level(SPL)of 14 types of bundle conductors is investigated by using an ultra-high-voltage(UHV)corona cage(8 m×8 m×35 m)at an altitude of 2216 m,where the bundle numbers between 4 and 12 and the conductor types are used in 500 kV,750 kV or 1000 kV power transmission projects.Then a large number of valuable AN data are obtained;the influences of bundle numbers and sub-conductor diameters on an acoustic power density level(LPWL)are analyzed;and an A-weighted LPWL calculation method is proposed.In addition,by comparing the AN data obtained from the low-altitude area(altitude:23 m),the AN altitude correction factor is concluded,and the influences of conductor parameters and the surface electric field strength on correction factors are discussed.The results obtained in this paper can provide important data for the construction of high-altitude AC power lines.Wangling He Baoquan Wan Shilong Huang Yunpeng Liu Jiangong Zhang Xiao Han 2023CSEE Journal of Power and Energy Systems2023,9,6:0
8Dispersion characteristics of switching transients from large‐scale experiments in a 1100 kV gas insulated switchgear circuit显示文摘The switching operation of gas insulated switchgear(GIS)disconnector will produce multiple random spark discharges between the gas gaps of the disconnector.Each spark discharge can be affected by various random factors,such as trapped charge on the load side,the initial operating phase,gap distance and operating speed of the disconnector,leading to dispersion characteristics.At present,some studies have mentioned this dispersion,but its impact is still unclear due to the lack of experimental data,resulting in a deviation between the simulation results and the measured results.In this study,thousands of switching operations were carried out based on the 1100 kV full‐scale GIS circuit in Wuhan ultra‐high voltage alternating current Test Base.The maximal information coeffi-cient analysis,linear regression fitting and other statistical methods were used to discuss the dispersion characteristics of very fast transient overvoltage(VFTO)and transient enclosure voltage(TEV)from large‐scale experimental data.The results show that the dispersion of VFTO and TEV in amplitude aspects both increase gradually as the breakdown voltage increases,with the maximum difference of five times of TEV amplitude at normalised breakdown voltage.In terms of frequency characteristics,the dispersion of different fre-quency components in TEV is always greater than that of VFTO,especially for the high‐frequency components.Moreover,by comparing the frequency characteristics of TEV at different positions,we notice that the dispersion is almost independent of the spatial po-sition but only determined by the randomness of spark discharges.These discoveries reveal the importance of the dispersion in switching transients and make up for the lack of theoretical understanding of the correlation among them.Zihan Teng Weijiang Chen Jiangong Zhang Baoquan Wan Jun Zhao Kejie Li Zhenghai Liao Zheyuan Gan 2023High Voltage2023,8,6:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费