维普中文期刊产品整合服务
3篇 您的检索式:作者名="Mingtao Kang"
    题名 作者 年代 出处 被引量
1The C_(6)D_(6)detector system on the Back-n beam line of CSNS显示文摘Introduction The neutron capture cross sections are very important in the field of nuclear device design and basic physics research.Hydrogen-free liquid scintillator such as C_(6)D_(6)detectors are widely used in the neutron capture cross-sectional measurements for the low neutron sensitivity and fast time response.The Back-n white neutron source at China Spallation Neutron Source is the first spallation white neutron source in China,and it is suitable for neutron capture cross-sectional measurement.Materials and methods A C_(6)D_(6)detector system was built in the Back-n experimental station.The pulse height weighting technique was used to determine the system’s detection efficiency.The response to gamma rays of the C_(6)D_(6)detector was measured,and the energy resolution function was determined.Monte Carlo simulation with Geant4 code was carried out to get the weighting function of this C_(6)D_(6)detector system.Additionally,the systematic uncertainty of the weighting function was also determined.Conclusion According to the experimental and simulation results,this C_(6)D_(6)detector system can be used to measure neutron capture cross section.Jie Ren Xichao Ruan Jie Bao Guangyuan Luan Wei Jiang Qi An Huaiyong Bai Ping Cao Qiping Chen Yonghao Chen Pinjing Cheng Zengqi Cui Ruirui Fan Changqing Feng Minhao Gu Fengqin Guo Changcai Han Zijie Han Guozhu He Yongcheng He Yuefeng He Hanxiong Huang Weiling Huang Xiru Huang Xiaolu Ji Xuyang Ji Haoyu Jiang Hantao Jing Ling Kang Mingtao Kang Bo Li Lun Li Qiang Li Xiao Li Yang Li Yang Li Rong Liu Shubin Liu Xingyan Liu Yinglin Ma Changjun Ning Binbin Qi Zhaohui Song Hong Sun Xiaoyang Sun Zhijia Sun Zhixin Tan Hongqing Tang Jingyu Tang Pengcheng Wang Qi Wang Taofeng Wang Yanfeng Wang Zhaohui Wang Zheng Wang Jie Wen Zhongwei Wen Qingbiao Wu Xiaoguang Wu Xuan Wu Likun Xie Yiwei Yang Han Yi Li Yu Tao Yu Yongji Yu Guohui Zhang Jing Zhang Linhao Zhang Liying Zhang Qingmin Zhang Qiwei Zhang Xianpeng Zhang Yuliang Zhang Zhiyong Zhang Yingtan Zhao Liang Zhou Zuying Zhou Danyang Zhu Kejun Zhu Peng Zhu 2019Radiation Detection Technology and Methods2019,3,3:1
2The machine protection system for CSNS显示文摘Background The China Spallation Neutron Source(CSNS)accelerator consists of an 80 MeV H-LINAC,a 1.6 GeV rapid cycling synchrotron(RCS)and two beam transport lines.The uncontrolled beam may permanently damage the components or lead to very high residual radiation dose along the beam line.So the equipment protection must be deliberately designed and implemented.Purpose The machine protection system(MPS)protects components from being damaged by the beam.The response time requirement for the CSNS MPS is less than 20 ms,so the PLC(programmable logic controller)was adopted to implement the interlock logic.Methods The MPS was implemented as a two-tier architecture system,and developed through utilizing PLC and Experimental Physics and Industrial Control System(EPICS)software toolkits.The application logic was taken into careful consideration during the implementation stage.An embedded CPU module can function as an IOC accessing PLC I/O modules through the sequence CPU,with an embedded Linux operation system.Results The interlock logic and heartbeat functions were tested with all functions ok.Time consumption has been measured thoroughly since the important requirement,which is around 15 ms to stop the beam.Conclusions MPS was completed in Sep.2017 and then put into operation.It has been operating smoothly for more than 3 years.MPS has played an important role in every stage of CSNS’s commissioning and operation and achieved high reliability during the user’s experiment operation.The accelerator recently runs stably with low equipment failure.Kang Mingtao Zhang Yuliang Jin Dapeng He Yongcheng Zhan Mingchuan Zhu Peng Wu Xuan Guo Fengqin Wang Lin 2021Radiation Detection Technology and Methods2021,5,2:1
3The run management system for CSNS显示文摘Purpose In order to increase CSNS beam power from 100 to 500 kW,the linac injection energy needs to be increased from 80 to 300 MeV.The combined layout of superconducting spoke cavities and elliptical cavities will be adopted to accelerate H−beam to 300 MeV.In this paper,a compact single spoke cavity withΦ50-mm beam aperture was proposed,with the RF performance of the spoke cavity optimized to Ep/Eacc<5,Bp/Eacc<9,as well as the good multipacting behavior.Methods CST Microwave Studio was used to optimize the RF performance(Epeak/Eacc,Bpeak/Eacc,R/Q)with cavity geometry parameters.After electromagnetic design was finished,multipacting behavior was studied with CST Particle Studio module,and cavity shape modification was made to get a reasonablevalue.Results The simulation got optimum results of Epeak/Eacc=4.97 and Bpeak/Eacc=8.42 mT/(MV/m),and themax is 1.52 at Eacc=7.74 MV/m.Conclusion A 648 MHzβg=0.4 single spoke cavity with beam apertureΦ50 mm was proposed in the paper.This compact cavity may be a very promising option for CSNS linac upgrading.In addition to the optimization of the RF parameters,the multipacting behavior of the cavity is also studied,and cavity shape is optimized to reducevalue.Yuliang Zhang Mingtao Kang Dapeng Jin Yongcheng He Peng Zhu Xuan Wu Fengqin Guo Lin Wang Wenchun Gao Gang Li 2019Radiation Detection Technology and Methods2019,3,3:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费