维普中文期刊产品整合服务
3篇 您的检索式:作者名="Zonghui Guo"
    题名 作者 年代 出处 被引量
1A Point-of-Care Test System for Biochemical Blood Analysis Based on ADUC824显示文摘A point-of-care test system has been studied in this paper.It was used to determine substances in blood such as Hemoglobin (HB),Aspartate Aminotransferase (AST),Creatine Kinase (CK) and so on.Based on the principle of amperometric determination,the research on detecting weak current signals was carried on.At the same time as to the weak signals (nA level),magnifying,sampling and processing the signals were also studied.Controlled by ADUC824 and assisted by other units, every substance could be determined automatically and rapidly integrated with the corresponding biosensor.In the experiment, the minimum detectable current of the instrument (YT2005-1) is 0.2 nA.With regard to the 1 nA which the experiment demanded,it could be up to the mustard.And the system can provide results in 180 s with a long term stability.Hui Wang Qing Tian Liying Jiang Chunxiu Liu Zonghui Guo Xinxia Cai 2006稀有金属材料与工程2006,35,A03:0
2Amperometric Enzyme Biosensor for the Determination of High Concentration Lactate in Whole Blood of Athletes显示文摘<正>Amperometric biosensor applied to the determination of high concentration lactate in serum and whole blood was described.The biosensor was constructed by gold electrode modified with nanoplatinum particles.Lactate oxidase (E.C.1.1.3.2) was immobilized at platinized activated gold electrode which was used for the determination of high concentration lactate at low potential (+0.2 V).The linear calibration graphs were obtained from 1 to 21 mmol·L~ (-1) lactate in serum and from 0.9 to 13.2 mmol.L~ (-1) lactate in whole blood.The correlation coefficients were 0.99 and 0.97,respectively at a steady-state response time of 50 s.Chunxiu Liu Zonghui Guo Hui Wang Jianfang Xu Lianshi Feng Xinxia Cai 2006稀有金属材料与工程2006,35,A03:0
3Development of Enzyme Biosensor for Amperometric Measurement of Aspartate Aminotransferase显示文摘An enzyme biosensor for amperometric measurement of aspartate aminotransferase has been developed.The working electrode was modified with a thin-film of redox polymer,then glutamate oxidase,with the immobilized reagent cast and dried on the electrode.The biosensor responses to AST by detecting hydrogen peroxide were produced by enzymical reaction at-0.1 V with a response time of 120 seconds.The electrode gave a detection limit of 32.5 U/L with a linear concentration range of 32.5 U/L~2000 U/L in serum.Due to more sensitive and lower detection limit,the biosensor is expected mainly to be used for physiological identification and physical performance of athletes in the future.Extended application will also affect the practice of clinical medicine for the diagnosis of heart and liver disease.Zonghui Guo Chunxiu Liu Huaqing Li Jianfang Xu Lianshi Feng Xinxia Cai 2006稀有金属材料与工程2006,35,A03:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费