|
|
|
题名
|
作者
|
年代
|
出处
|
被引量
|
| 1 | Effect of orthokeratology on precision and agreement assessment of a new sweptsource optical coherence tomography biometer显示文摘Background:To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography(SS-OCT)optical biometer(OA-2000),and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry(PCI).Methods:This study recruited fifty-one eyes of 51 normal children(8–16 years).An operator took measurements with the two biometers.Then,a second operator took measurements with the SS-OCT biometer.After orthokeratology was performed for one month,the same operators repeated the same procedures.Axial length(AL),mean keratometry(Km)at 2.5 mm and 3.0 mm diameters(Km2.5 and Km3.0),central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT)and corneal diameter(CD)were analyzed.Results:With the SS-OCT optical biometer,the test-retest repeatability of AL measurements was<0.06 mm.For all parameters,the coefficients of variation were<1.23%and the intraclass correlation coefficients were>0.95.The 95%limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm.After orthokeratology,the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology,while the absolute values of difference for AL,Km2.5,ACD and CD measurements were comparable.Conclusions:Before and after orthokeratology,the SS-OCT biometer showed high repeatability and reproducibility for all measurements.Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements.The CD measurement showed poor agreement between the two devices. | Bao Shu Fangjun Bao Giacomo Savini Weicong Lu Ruixue Tu Haisi Chen Benhao Song Qinmei Wang Jinhai Huang | 2020 | Eye and Vision2020,7,1: | 1 |
| 2 | Sirius Scheimpflug–Placido versus ultrasound pachymetry for central corneal thickness:meta-analysis显示文摘Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was−11.26μm with a 95%confidence interval(CI)(−16.92μm,−5.60μm).The heterogeneity was I^(2)=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. | Yili Jin Colm McAlinden Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang | 2021 | Eye and Vision2021,8,1: | 1 |
| 3 | The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging显示文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems. | Yune Zhao Ding Chen Giacomo Savini Qing Wang Hongfang Zhang Yili Jin Benhao Song Rui Ning Jinhai Huang Chenyang Mei | 2020 | Eye and Vision2020,7,1: | 1 |
| 4 | Sirius Scheimpflug-Placido versus. ultrasound pachymetry for central corneal thickness: meta-analysis显示文摘Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. | Yili Jin Colm McAlinden Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang | 2023 | Eye and Vision2023,9,4: | 0 |
| 5 | Rapidity,Transverse Mass Distributions and Nuclear Stopping in(14.6 AGeV/c)Si+A u Reactions显示文摘The experimental data of proton and pion rapidity distributions and proton transverse mass distribution in rcaction of(14.6AGeV/c)Si+Au are compared with a simple relativistic hadronic cascade simulation.The theoretical results seem to prefer the statement of strong but incomplete nuclear stopping at AGS energy. | WANG Zhongqi SA Benhao LU Zhongda ZHANG Xiaoze SONG Guang ZHENG Yuming | 1993 | Chinese Physics Letters1993,10,8: | 0 |
| 6 | The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging显示文摘Purpose:To assess the repeatability and reproducibility of swept-source optical coherence tomography(SS-OCT)and Scheimpflug system and evaluate the agreement between the two systems in measuring multiple corneal regions in children.Methods:Pachymetric and keratometric maps for both systems were evaluated.Central,midperipheral and peripheral corneal thickness(CT),keratometry and astigmatism power vectors were recorded.The three outcomes yielded by the same observer were used to assess intraobserver repeatability.The differences in the mean values provided by each observer were used to evaluate interobserver reproducibility.Within-subject standard deviation,test-retest repeatability(TRT)and coefficient of variation(CoV)were used to analyze the intraobserver repeatability and interobserver reproducibility.Paired T-test and Bland-Altman were used to appraise interdevice agreement.Results:Seventy-eight eyes of 78 children were included.The CoV was≤2.12 and 1.10%,respectively,for repeatability and reproducibility.TRT and CoV were lower for central and paracentral CT measurements than for peripheral measurements.The SS-OCT device generated higher precision when acquiring CT data,whereas Scheimpflug system showed higher reliability when measuring corneal keratometry.Although the CT readings measured using SS-OCT were significantly thinner than Scheimpflug device(P<0.001),the central and thinnest CT values were still of high agreement.The interdevice agreement of keratometry measurement was high for the central corneal region and moderate for the paracentral and peripheral areas.Conclusions:The precision of CT measurements by SS-OCT was higher,while the reliability of keratometry measurements by the Scheimpflug system was higher in children.Apart from the measured values in the central corneal region,the thickness and keratometry readings should not be considered interchangeable between the two systems. | Yune Zhao Ding Chen Giacomo Savini Qing Wang Hongfang Zhang Yili Jin Benhao Song Rui Ning Jinhai Huang Chenyang Mei | 2022 | Eye and Vision2022,8,5: | 0 |