| 1 | Discharge Characteristics of Long SF6 Gas Gap with and Without Insulator in GIS Under VFTO and LI显示文摘Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses. | Tao Wen Qiaogen Zhang Jingtan Ma Can Guo Haoyang You Yifan Qin Yu Yin Weidong Shi Weijiang Chen | 2015 | CSEE Journal of Power and Energy Systems2015,1,3: | 17 |
| 2 | Recent Developments of FNET/GridEye—A Situational Awareness Tool for Smart Grid显示文摘Wide-area monitoring systems(WAMS)are becoming increasingly vital for enhancing power grid operators’situational awareness capabilities.As a pilot WAMS that was initially deployed in 2003,the frequency monitoring network FNET/GridEye uses GPS-time-synchronized monitors called frequency disturbance recorders(FDRs)to capture dynamic grid behaviors.Over the past ten years,a large number of publications related to FNET/GridEye have been reported.In this paper,the most recent developments of FNET/GridEye sensors,data centers,and data analytics applications are reviewed.These works demonstrate that FNET/GridEye will become a costeffective situational awareness tool for the future smart grid. | Yong Liu Wenxuan Yao Dao Zhou Ling Wu Shutang You Hesen Liu Lingwei Zhan Jiecheng Zhao Haoyang Lu Wei Gao Yilu Liu | 2016 | CSEE Journal of Power and Energy Systems2016,2,3: | 2 |
| 3 | Electrical characteristics of new three-phase traction power supply system for rail transit显示文摘A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%. | Xiaohong Huang Hanlin Wang Qunzhan Li Naiqi Yang Tao Ren You Peng Haoyang Li | 2023 | Railway Engineering Science2023,31,1: | 0 |
| 4 | A novel co-catalyzed system between persulfate and chlorite by sonolysis for removing triphenylmethane derivative显示文摘Triphenylmethane(tpm) derivatives(e.g. tpm CV) have threatened the safety of the aquatic environment due to the potential toxicity and carcinogenicity. In this study, the novel ultrasonic/persulfate/chlorite(US/S_(2)O_(8)^(2-)/ClO_(2)^(-)) oxidation process was developed for the effective removal of tpm CV in wastewater. The apparent non-integer kinetics( n around 1.20) of tpm CV degradation under different factors( R^(2)_(Adj) > 0.990) were investigated, respectively. Inhibiting effects of anions were greater than those of cations(except Fe(Ⅱ/Ⅲ)). The adding of micromolecule organic acids could regulate degradation towards positive direction. The double response surface methodology(RSM) was designed to optimize tpm CV removal process, and the acoustic-piezoelectric interaction was simulated to determine the propagation process of acoustic wave in the reactor. The possible degradation pathway was explored to mainly include carbonylation, carboxylation, and demethylation. The estimated effectivemean temperature at the bubble-water interface was calculated from 721 to 566 K after introducing the ClO_(2)^(-), however, the adsorption or partitioning capacity of tpm CV in the reactive zone was widened from 0.0218 to 0.0982. The proposed co-catalysis of US/S_(2)O_(8)^(2-)/ClO_(2)^(-)was based on the determined active species mainly including ClO_(2), SO_(4)·^(-), and ·OH. Compared with other US-based processes, the operating cost(3.97 $/m^(3)) of US/S_(2)O_(8)^(2-)/ClO_(2)^(-)with the EE/O value(16.8 k Wh/m^(3)) was relatively reduced. | Qihui Xu Haoran Leng Hong You Shutao Wang Haoyang Li Yibo Yu | 2022 | Journal of Environmental Sciences2022,34,2: | 0 |