维普中文期刊产品整合服务
5篇 您的检索式:作者名="Shutang You"
    题名 作者 年代 出处 被引量
1Recent Developments of FNET/GridEye—A Situational Awareness Tool for Smart Grid显示文摘Wide-area monitoring systems(WAMS)are becoming increasingly vital for enhancing power grid operators’situational awareness capabilities.As a pilot WAMS that was initially deployed in 2003,the frequency monitoring network FNET/GridEye uses GPS-time-synchronized monitors called frequency disturbance recorders(FDRs)to capture dynamic grid behaviors.Over the past ten years,a large number of publications related to FNET/GridEye have been reported.In this paper,the most recent developments of FNET/GridEye sensors,data centers,and data analytics applications are reviewed.These works demonstrate that FNET/GridEye will become a costeffective situational awareness tool for the future smart grid.Yong Liu Wenxuan Yao Dao Zhou Ling Wu Shutang You Hesen Liu Lingwei Zhan Jiecheng Zhao Haoyang Lu Wei Gao Yilu Liu 2016CSEE Journal of Power and Energy Systems2016,2,3:2
2Impact of Simultaneous Activities on Frequency Fluctuations:Comprehensive Analyses Based on Real Measurement Data from the FNET/GridEye显示文摘Simultaneous human activities,such as the Super Bowl game,would cause certain impacts on frequency fluctuations in power systems.With the help of FNET/GridEye measurements,this paper aims to give comprehensive analyses on the frequency fluctuations during Super Bowl LIV held on Feb.2,2020,so as to better understand several phenomena caused by simultaneous activities which will help system operations and controls.First,recent developments of the FNET/GridEye are briefly introduced.Second,the frequency fluctuations of the Eastern Interconnection(El),western electricity coordinating council(WECC),and electric reliability council of Texas(ERCOT)power systems during Super Bowl LIV are analyzed.Third,frequency fluctuations of Super Bowl Sunday and ordinary Sundays in 2020 are compared.Finally,the differences of frequency fluctuations among different years during the Super Bowl and their change trends are also given.Furthermore,several possible explanations,including the simultaneity of electricity consumption at the beginning of commercial breaks and the halftime show,the increasing usage of the Internet,and the increasing size of TV screens,are illustrated in detail in this paper.Shengyuan Liu Shutang You Chujie Zeng Yinfeng Zhao Wenxuan Yao Yilu Liu Zhenzhi Lin 2021CSEE Journal of Power and Energy Systems2021,7,2:1
3Oscillation mode identification based on wide-area ambient measurements using multivariate empirical mode decomposition显示文摘Shutang You 2016Electric Power System Research2016,,134:1
4Adding power of artificial intelligence to situational awareness of large interconnections dominated by inverter‐based resources显示文摘Large‐scale power systems exhibit more complex dynamics due to the increasing inte-gration of inverter‐based resources(IBRs).Therefore,there is an urgent need to enhance the situational awareness capability for better monitoring and control of power grids dominated by IBRs.As a pioneering Wide‐Area Measurement System,FNET/GridEye has developed and implemented various advanced applications based on the collected synchrophasor measurements to enhance the situational awareness capability of large‐scale power grids.This study provides an overview of the latest progress of FNET/GridEye.The sensors,communication,and data servers are upgraded to handle ultra‐high density synchrophasor and point‐on‐wave data to monitor system dynamics with more details.More importantly,several artificial intelligence(AI)‐based advanced appli-cations are introduced,including AI‐based inertia estimation,AI‐based disturbance size and location estimation,AI‐based system stability assessment,and AI‐based data authentication.Lin Zhu Yinfeng Zhao Yi Cui Shutang You Wenpeng Yu Shengyuan Liu He Yin Chang Chen Yuru Wu Wei Qiu Mirka Mandich Hongyu Li Adedasola Ademola Chengwen Zhang Chujie Zeng Xinlan Jia Weikang Wang Haoyu Yuan Huaiguang Jiang Jin Tan Yilu Liu 2021High Voltage2021,6,6:0
5Automated Two-stage Conversion of Hourly Optimal DC Flow Solution to AC Power Flow显示文摘Conversion of hourly dispatch cases derived using DC optimal power flow(DCOPF)to AC power flow(ACPF)case is often challenging and requires arduous human analysis and intervention.This paper proposes an automated two-stage approach to solve ACPF formulated from DCOPF dispatch cases.The first stage involved the use of the conventional Newton Raphson method to solve the ACPF from flat start,then ACPF cases that are unsolvable in the first stage are subjected to a hotstarting incremental method,based on homotopy continuation,in the second stage.Critical tasks such as the addition of reactive power compensation and tuning of voltage setpoints that typically require human intervention were automated using a criteriabased selection method and optimal power flow respectively.Two datasets with hourly dispatches for the 243-bus reduced WECC system were used to test the proposed method.The algorithm was able to convert 100%of the first set of dispatch cases to solved ACPF cases.In the second dataset with suspect dispatch cases to represent an extreme conversion scenario,the algorithm created solved ACPF cases that satisfied a defined success criterion for 77.8%of the dispatch cases.The average run time for the hotstarting algorithm to create a solved ACPF case for a dispatch was less than 1 minute for the reduced WECC system.Adedasola A.Ademola Shutang You Yilu Liu 2023CSEE Journal of Power and Energy Systems2023,9,1:0
返回顶部 每页显示:
共1页 首页 上一页 第1页 下一页 末页 /1 跳转

网站首页 | 关于我们 | 联系我们 | 产品服务 | 客服中心 | 广告服务 | 版权声明 | 网站联盟 | 友情链接 | 售卡网点

版权所有© 渝B2-20050021-1 渝公网安备 50019002500403号 违法和不良信息举报中心

互联网出版许可证 新出网证(渝)字10号 全国400电话 - 免长途话费